← All posts
Sustainability5 min read

Scope 1, 2 and 3 Emissions for Real Estate Portfolios

Scope 1 is fuel burned on site, Scope 2 is purchased electricity and heat, and Scope 3 covers the value chain, including energy tenants buy in leased space.

For a property portfolio, Scope 1 is fuel burned on site in equipment the owner controls, such as gas boilers. Scope 2 is the electricity, steam, heat or cooling the owner buys. Scope 3 is everything else in the value chain, which for a landlord usually includes the energy tenants buy for the space they lease.

The scopes come from the GHG Protocol, and most reporting frameworks build on them. Where a given utility bill lands depends on who controls the space and who pays the account.

What are Scope 1, 2 and 3 emissions?

The GHG Protocol Corporate Standard classifies a company's greenhouse gas emissions into three scopes. Its own summary reads: Scope 1 emissions are direct emissions from owned or controlled sources, Scope 2 emissions are indirect emissions from the generation of purchased energy, and Scope 3 emissions are all other indirect emissions that occur in the reporting company's value chain, upstream and downstream. Source: GHG Protocol, Scope 3 FAQ.

The US Environmental Protection Agency uses the same definitions. It gives fuel combustion in boilers, furnaces and vehicles as examples of Scope 1, and describes Scope 2 as indirect emissions associated with the purchase of electricity, steam, heat or cooling. Scope 2 emissions physically occur at the power plant, and they are counted in the buyer's inventory because they result from the buyer's energy use. Source: EPA, Scope 1 and Scope 2 Inventory Guidance.

How do the scopes map to a property portfolio?

SourceTypical scope for the ownerData you need
Natural gas burned in owner-controlled boilers and water heatersScope 1Gas bills in therms or cubic feet
Fuel oil or propane for owner-controlled equipmentScope 1Delivery invoices in gallons
Electricity on owner-paid accounts, such as common areas and vacant unitsScope 2Electric bills in kilowatt-hours
Purchased district steam, heating or coolingScope 2Supplier invoices
Electricity and gas that tenants buy on their own accountsScope 3Tenant data, utility aggregated data or estimates

The table shows a common outcome. Your own result depends on how you set your organizational boundary, which is the next question.

Who reports the energy used in leased space?

The answer depends on the lease and the boundary. The GHG Protocol's guidance on leased assets says leased assets may be included in a company's Scope 1 or Scope 2 inventory depending on the type of lease and the consolidation approach the company uses to define its organizational boundaries.

For a landlord, the Scope 3 Standard provides Category 13, downstream leased assets. It covers emissions from the operation of assets the reporting company owns and leases to others that are not already included in its Scope 1 or Scope 2. The guidance adds that a lessor's Category 13 emissions include the Scope 1 and Scope 2 emissions of its lessees. Source: GHG Protocol, Category 13 technical guidance.

Tenants look at the same building from the other side. A company that operates leased space refers to Category 8, upstream leased assets.

Under an operational control boundary, which many owners use, the split typically looks like this:

Write the boundary rule down once and apply it to every property. Auditors and investors ask for the rule before they look at the numbers.

What are location-based and market-based Scope 2?

The GHG Protocol Scope 2 Guidance, published in 2015, standardizes how companies measure emissions from purchased electricity, steam, heat and cooling. It describes two methods. The location-based method uses the average emissions of the grid where the energy is consumed. The market-based method reflects the electricity a company has chosen to buy through contracts and energy attribute certificates, and the guidance sets quality criteria those instruments must meet. Source: GHG Protocol, Scope 2 Guidance.

The guidance is under revision. The GHG Protocol held a public consultation on Scope 2 from October 20, 2025 to January 31, 2026. Check its site for the status before you set a multi-year method.

For US location-based figures, the usual source of grid factors is EPA's eGRID database, which covers the environmental characteristics of nearly all US electricity generation. The latest edition holds 2023 data. Source: EPA eGRID.

How large is Scope 3 for a landlord?

It depends on the portfolio, and no single percentage applies. The Scope 3 Standard, published in 2011, organizes value chain emissions into 15 categories. Source: GHG Protocol, Corporate Value Chain (Scope 3) Standard.

A portfolio where residents hold their own utility accounts, such as single-family rentals, will have most of its operational energy in Category 13. A master-metered portfolio will have most of it in Scope 1 and Scope 2. The same buildings can produce very different scope splits under different metering arrangements, which is why scope totals should be read alongside whole-building energy use.

How do investor benchmarks treat the scopes?

Benchmarks apply the same scopes with their own rules. GRESB's 2025 Real Estate Reference Guide states that Scope 3 emissions in its assessment are calculated as the emissions associated with tenant areas, unless they are already reported as Scope 1 or Scope 2. It excludes upstream supply chain emissions and emissions from the entity's own employees. GRESB's 2026 updates include a reclassification of GHG scopes for closer alignment with industry frameworks, so check the current guide. Source: GRESB 2025 Real Estate Reference Guide.

For day-to-day tracking, EPA's ENERGY STAR Portfolio Manager tracks energy, water, waste and greenhouse gas emissions for buildings in one tool. Source: ENERGY STAR, Benchmark your building.

What data do you need to calculate each scope?

  1. A list of every utility account and meter, by property, with the account holder.
  2. Twelve months of consumption in physical units. Kilowatt-hours, therms and gallons, taken from bills. Dollar amounts are not enough.
  3. Service dates for each bill, so use lands in the right reporting year.
  4. The grid region for each property, to select the right electricity factor.
  5. Occupancy and lease dates, to assign each month to the owner or the tenant.
  6. Tenant consumption for space where tenants hold the account, from the tenant, from the utility's aggregated data where it is offered, or from a documented estimate.
  7. A record of every estimate, with the method used.

Most of this is already printed on utility bills. The work is capturing it consistently, for every account, every month.

How AirBills handles it

AirBills captures consumption and service dates from every utility bill and maintains a Scope 1 and Scope 2 inventory from that data, using eGRID subregion factors for electricity. Any Scope 2 figure can be drilled down to the factor used and the bill behind it. See Sustainability and ESG.

Billing That Runs Itself

Automate tenant billing, cut disputes, and reclaim hours every week.

Book a Demo